This is an addendum to the CFW-09 frequency inverter manual. It introduces the new functions of the product.
This document is an addendum to the CFW-09 Frequency Inverter Manual, detailing new features in software version V4.40, including mechanical brake logic and updated parameter incompatibilities. It specifies how to configure parameters for brake activation and lists new error codes (E24) for incompatible settings. The document is intended for qualified personnel to ensure safe installation and operation of the inverter.
| Software Version | V4.40 |
|---|---|
| Document Number | 10001151840 / 00 |
| Publication Date | 03/2011 |
Parameter P203 selects the special function type: 0 = Not Used, 1 = PID Regulator, 2 = Mechanical Brake Logic.
The brake activates based on speed comparison: N > Nx or N*t > Nx, with conditions including being in Run mode and without error.
New E24 incompatibilities include combinations of parameters like P225 ≠ 0 with P275 = 30 or 31, or P265 = 10 with P275 = 30 or 31.