About this manual

This guide explains how to set up and use the DC745 demonstration circuit board to evaluate the LTC2433-1 16-bit differential input delta sigma ADC. It includes hardware setup instructions, connection to the DC590 USB Serial Controller, and basic experiments to demonstrate input noise, common mode rejection, and bipolar symmetry. The board is designed for easy prototyping and direct connection to target applications.

What's inside

  • Quick Start Procedure
  • Hardware Setup
  • Connection to DC590
  • Analog Connections
  • Experiments

Specifications

ADC Resolution16-bit
Linearity0.12 LSB
Full-Scale Accuracy0.16 LSB
Input Noise1.45mV RMS
Common Mode Rejection140 dB

Frequently asked questions

How do I connect the DC745 to a host PC?

Connect DC745 to a DC590 USB Serial Controller using the supplied 14-conductor ribbon cable, then connect the DC590 to the host PC with a standard USB A/B cable.

What is the default reference voltage source?

The default reference voltage source is 5.00 volts from the onboard LT1236 reference.

What is the maximum trigger frequency when Fo is grounded?

The maximum trigger frequency is 5Hz when Fo is grounded.