Moog Submux1 RS-232/422/485 Submultiplexer User Manual

This manual introduces the Moog Components Group Submux1's RS-232/422/485 Submux Motherboard (P/N 970381-xxx) and Daughter-cards (4 ch. RS-232 P/N 970391-xxx, 4ch. RS-485 / 2 ch. RS422 P/N 980430-xxx, and Trigger Interface P/N 200700-XXX) use methods and troubleshooting guidance.


Moog Submux1 RS-232/422/485 Submultiplexer User Manual - cover page
Brand
MOOG
Category
Other Electronics
Document type
User Manual
Language
English
Pages
19
File format
PDF
File size
610 KB
Published
16 October, 2023
Updated
16 October, 2023
MD5 checksum
8A72825E1EFF98B0D174E1A55245C305

About this manual

This manual covers the Moog Components Group Submux1, a motherboard that multiplexes four RS-232 channels onto a single high-speed serial data channel. It details operation, specifications, and dimensions for the motherboard and up to three additional pluggable daughter boards (RS-232, RS-485, RS-422, and Trigger Interface), allowing for a total of 16 independent serial channels.

What's inside

  • RS-232/422/485 Submux Motherboard Operation
  • RS-232/422/485 Submux Indicators
  • RS-232/422/485 Submux Specifications
  • RS-232/422/485 Submux Dimensions
  • RS-232/422/485 Submux Power Requirements
  • Submux Motherboard Troubleshooting
  • Data Loop-Back Test
  • RS-232 Driver Chip Channel Selection
  • 4-Channel RS-232 Daughterboard
  • 4-Channel RS-485 / 2-Channel RS-422 Daughterboard

Specifications

Number of data Channels (Motherboard)4 (RS-232 only), up to 16 total with 3 daughtercards
Data type supportedRS-232, RS-422, and RS-485
RS-232 Data ratesup to 115 Kbaud
RS-485 Data ratesup to 115 Kbaud
RS-422 Data ratesup to 230 Kbaud
Per channel sample rate (-002 boards)4.5 Msps (typical)
Per channel sample rate (-001 boards)3.125 Msps (typical)
Dimensions (VME 3-U format)100 mm wide x 160 mm long x 20 mm thick
Power Requirements+5 Volts at 0.65 Amps

Frequently asked questions

What is the maximum data rate for RS-232 channels?

The maximum data rate for RS-232 channels is up to 115 Kbaud.

What is the maximum data rate for RS-422 channels?

The maximum data rate for RS-422 channels is up to 230 Kbaud.

How many total independent serial channels can be supported?

A total of 16 independent serial channels can be carried on a single Submux with the addition of up to three additional pluggable daughter boards.

What indicates that the Submux board is receiving data from the multiplexer?

The left LED of the dual green LED indicator (LED2), labeled RLINK, will be lit green if the board is receiving both RX clock and RX data.

Download PDF (610 KB)

More MOOG Manuals


View all MOOG manuals →