This is an instruction manual that introduces the features and usage methods of iPW1/iPW1EURO HF/50 MHz ALL BAND 1 kW LINEAR AMPLIFIER.
This manual provides instructions for the Icom IC-PW1 and IC-PW1EURO HF/50 MHz all-band 1 kW linear amplifiers. It details safety precautions, unpacking, and installation steps including grounding and antenna connections. The guide explains how to set up the remote controller and configure the amplifier for use with Icom Cl-V transceivers or non-Icom exciters.
| Power Output | 1 kW |
|---|---|
| Operating Temperature | -10°C to +40°C |
| Circuit Breaker Capacity | 20 A (U.S.A.) / 15 A (Europe) |
| ALC Control Voltage | -10 to 0 V DC |
| Send Control Max Level | 5.0 V DC/0.1 A |
No, the IC-PW1/EURO cannot be used with the AH-2 HF AUTOMATIC ANTENNA TUNER.
The transceiver's RF output power must be set to less than 100 W.
At least two persons must carry the linear amplifier.