ICP DAS I-7005/M-7005 User's Manual

I-7005/M-7005 User’s Manual is a product manual published by ICP DAS company. It mainly introduces the features and characteristics of the product, including product warranty, warning, copyright, trademark, size, terminal assignment, specifications, block diagrams, electrical connection, quick start, default settings, calibration, configuration tables, user-defined types, digital outputs and alarms, M-7000 notes, DIN rail mounting, etc.


ICP DAS I-7005/M-7005 User's Manual - cover page
Brand
icpdas
Category
Industrial Supply
Document type
User Manual
Language
English
Pages
160
File format
PDF
File size
1.8 MB
Published
12 October, 2023
Updated
12 October, 2023
Models
M-7005, I-7005
MD5 checksum
42192BD915B5A85EF27F58A86F1F8B89

About this manual

The I-7005/M-7005 is an 8-channel thermistor input and 6-channel digital output module designed for network data acquisition and control. It features a 24-bit sigma-delta ADC and supports various thermistor types including PreCon, Fenwell, and YSI models. Communication with the host is achieved via an RS-485 bi-directional serial bus using ASCII format commands.

What's inside

  • Introduction
  • Terminal Assignment
  • Specifications
  • Wiring
  • Quick Start
  • DCON Protocol
  • Modbus RTU Protocol
  • Troubleshooting
  • Mounting
  • Appendix

Specifications

Input Channels8
Input TypeThermistor
Sampling Rate8 samples/sec
Bandwidth5.24 Hz
Accuracy±0.1%
Output Channels6
Output TypeOpen collector
Output Load30 V, 100 mA max.
Power Requirement+10 to +30 VDC
Consumption1.1 W
Operating Temperature-25°C to +75°C
Maximum Resistance180000 ohms

Frequently asked questions

What is the maximum transmission speed?

Transmission speeds of up to 115.2 Kbps can be selected via software programming.

How long is the recommended warm-up period?

A warm-up period of 30 minutes is recommended to achieve complete performance results.