I-7005 and M-7005 User’s Manual

I-7005 and M-7005 User’s Manual

User Manual 165 pages · 1.4 MB · EN

The ICP DAS 1-7005 and M-7005 are network data acquisition and control modules featuring 8-channel thermistor input and 6-channel digital output capabilities. These modules support a 24-bit sigma-delta ADC for high accuracy and allow direct thermistor connection with software calibration options. Communication with the host is handled via an ASCII format over an RS-485 bi-directional serial bus with programmable baud rates up to 115.2 Kbps.

The manual provides detailed instructions on terminal assignments, wiring recommendations, and default settings. It includes comprehensive guides for the proprietary DCON protocol and the standard Modbus RTU protocol, detailing specific commands for reading digital output status, input status, and configuring module settings. Additionally, the document covers troubleshooting steps, mounting options (DIN-rail, piggyback, wall), and technical support information.

Read online

ICP DAS M-7005 specifications

Input Channels8
Input TypeThermistor
Sampling Rate8 samples/sec
Bandwidth5.24 Hz
Accuracy±0.1%
Output Channels6
Output TypeOpen collector
Output Load30 V, 100 mA max.
Power Requirement+10 to +30 VDC
Consumption1.1 W
Operating Temperature-25°C to +75°C
Maximum Resistance180000 ohms

Source: ICP DAS I-7005/M-7005 User's Manual

All ICP DAS M-7005 documents by type

User Manual 3

Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.

Questions answered in these manuals

What is the maximum transmission speed?

Transmission speeds of up to 115.2 Kbps can be selected via software programming.

From: ICP DAS I-7005/M-7005 User's Manual

How long is the recommended warm-up period?

A warm-up period of 30 minutes is recommended to achieve complete performance results.

From: ICP DAS I-7005/M-7005 User's Manual

What is the maximum resistance that can be measured?

The maximum resistance is 180,000 ohms for firmware version A2.3 and earlier, and 204,800 ohms for firmware version A3.7 and later.

From: I-7005 and M-7005 User’s Manual

What is the maximum resistance the 1-7005 and M-7005 can measure?

The maximum resistance that can be measured is 180000 ohms for firmware version A2.3 and earlier, and 204800 ohms for firmware version A3.7 and later.

From: I-7005 and M-7005 User’s Manual

What is the maximum transmission speed for the modules?

Transmission speeds of up to 115.2 Kbps can be selected.

From: ICP DAS I-7005/M-7005 User Manual

What is the recommended warm-up period for the modules?

A warm-up period of 30 minutes is recommended to achieve complete performance results.

From: ICP DAS I-7005/M-7005 User Manual