This document describes the accessories, safety precautions, and specifications of the product. The product is intended for object detection and should not be used to protect the human body or in explosive environments. The product features different response times, LED indicators, and operation modes.
This document serves as the instruction manual for the KEYENCE Hybrid Fiberoptic Sensors, specifically models FS-V11(P), FS-V12(P), and FS-V10. It provides essential safety precautions, noting that the product is intended only for object detection and not for human protection or explosive environments. The manual details the product's specifications, including response times, power supply requirements, and environmental operating conditions.
| Response time | 250 µs (FINE)/500 µs (TURBO)/ 410 µs to 1.7 ms 1. 1 ms (SUPER) |
|---|---|
| Operation mode | LIGHT-ON/DARK-ON (switch selectable) |
| Control output | NPN or PNP open-collector 24V 100mA max. |
| Power supply voltage | 12 to 24 VDC ±10% |
| Ambient temperature | 3.-10 to +55 °C (14 to 131 °F), No freezing. |
| Relative humidity | 35 to 85%, No condensation |
No, this product is just intended to detect the object(s) and should not be used to protect a human body.
No, it is not intended for use as an explosion-proof product and should not be used in hazardous locations.
The sensor can operate under an ambient illumination of up to 20,000 lx of sunlight.