This manual provides installation, usage, and maintenance instructions for the Winsen MEu-2CO electrochemical carbon monoxide sensor.
The document is a user manual for the Winsen MEu-2CO, an electrochemical fuel cell type sensor designed to detect carbon monoxide (CO) concentrations. The device operates by measuring current generated from oxidation-reduction reactions between CO and oxygen on working electrodes, which correlates with gas concentration according to Faraday's Law. This manual is written in Chinese.
| Detected Gas | Carbon Monoxide (CO) |
|---|---|
| Range | 0~500ppm |
| Maximum Load | 1000ppm |
| Sensitivity | (45±15) nA/ppm |
| Response Time (T90) | <15S |
| Zero Output Drift (-10℃~+50℃) | <+10ppm (equivalent CO) |
| Repeatability | <±3% output value |
| Stability (Average Decay/Month) | <2% |
| Operating Temperature Range | -10℃~+50℃ |
| Expected Service Life | 8 years (in air) |
The expected service life is 8 years when used in air.
The aging time before use should not be less than 48 hours.
Yes, at a concentration of 200ppm hydrogen produces an equivalent CO response of 40ppm.