This manual provides usage instructions, technical specifications, and handling precautions for the Winsen MQ-2 combustible gas sensor.
The document is a user manual for the Winsen MQ-2 semiconductor gas sensor. It describes the product's operation principle based on tin dioxide (SnO2) conductivity changes when detecting combustible gases like propane and smoke. The guide covers standard circuit conditions, including required heating and test voltages. This manual is written in Chinese.
| Detection Gas | Combustible gas, Smoke |
|---|---|
| Detection Concentration Range | 300~10000ppm |
| Standard Circuit Voltage (Vc) | 5.0V±0.1VDC |
| Heating Voltage (VH) | 5.0V±0.1VAC or DC |
| Heating Resistance (RH) | 30Ω±3Ω at room temperature |
| Sensitivity Ratio | ≥5 in air vs 2000ppm C3H8 |
| Output Voltage Range | 2.5V~4.0V in 2000ppm C3H8 |
| Preheat Time | Not less than 48 hours |
The sensor has high sensitivity to propane and smoke, and is ideal for detecting natural gas and other combustible vapors.
The standard test conditions require a loop voltage (Vc) of 5.0V±0.1VDC and a heating voltage (VH) of 5.0V±0.1VAC or DC.
The sensor requires a preheat time of not less than 48 hours to reach stability.