This manual provides usage instructions, technical specifications, and precautions for the Winsen WSP2110 organic vapor gas sensor.
The Winsen WSP2110 is a planar semiconductor gas sensor designed for detecting organic vapors such as toluene, benzene, and formaldehyde. It utilizes a thick-film manufacturing process with a metal oxide semiconductor sensing layer on a ceramic substrate, enclosed in a metal package. The sensor operates by changing its electrical conductivity in the presence of target gases, which can be converted into an output signal via a simple circuit. This manual is written in Chinese.
| Detected Gases | Toluene, Formaldehyde, Benzene, Alcohol, Acetone |
|---|---|
| Detection Concentration | 1~50ppm |
| Standard Circuit Voltage | VC ≤24VDC |
| Heating Voltage | 5.0V±0.1VAC or DC |
| Heating Resistance | 90Ω±10Ω (at room temperature) |
| Heating Power Consumption | ≤300mW |
| Preheating Time | Not less than 120 hours |
The sensor is sensitive to organic gases such as toluene, benzene, formaldehyde, alcohol, and acetone.
The sensor requires a preheating time of not less than 120 hours.