This document is an automation and chlorination operation manual, suitable for the model PL-P-4
The Hayward Pro Logic is a multifunction pool controller designed to fully manage pool and spa systems. It can control pumps, valves, lighting, heaters, and chlorination, offering both manual and automatic programmed operation modes. The system utilizes an optional chlorinator cell and plumbing kit to automatically generate free chlorine from salt for sanitization.
| Controlled Equipment | up to 4 high voltage (120/240V) pieces of equipment |
|---|---|
| Valve Actuators | up to 3 automatic valve actuators |
The ideal range for free chlorine is 1.0 - 3.0 ppm.
The recommended pH range is 7.2 - 7.8.
The ideal alkalinity level is between 80 and 120 ppm.