This is a user manual for Huawei laptop. Huawei laptop computer uses the latest Intel Core i7 processor, with 8GB of RAM and 1TB hard drive, equipped with a 15.6-inch full HD display. The laptop is only 17.9mm thick and weighs only 1.8kg, making it very portable.
This document provides technical specifications for the Buhler Technologies GAS 222.21 gas extraction probe (Sonde). The device is designed with a material of 1.4571 and features a ball valve made of 1.4408, utilizing PTFE/Graphite seals. This manual is written in German.
| Probe Material | 1.4571 |
|---|---|
| Valve Material | 1.4408 |
| Seals Material | PTFE/Graphite |
| Max Operating Temperature (Probe) | 200°C |
| Max Operating Pressure | 6 bar |
| Supply Voltage (Option A) | 230 V, 2.0A, 50/60Hz |
| Supply Voltage (Option B) | 115 V, 3.8 A, 50/60Hz |
| Temperature Range (Controller) | +50 to +200°C |
| Alarm Setting Range | 5...30K from setpoint |
| Switching Current Max | 1A |
| Protection Class | IP54 |
| Ambient Temperature Range | -20 to +70°C |
The part number for the 230V version is Art.Nr. 4622221.
The part number for the 115V version is Art.Nr. 4622225.
Information on accessories is found in data sheet DD461099.