Agilent ZORBAX SB-Aq Rapid Resolution High Definition Threaded Column Data Sheet

Agilent ZORBAX SB-Aq Rapid Resolution High Definition Threaded Column is a specially designed column for use with ultra-high performance liquid chromatographs (UHPLCs) such as the Agilent 1290 Infinity LC and can be used up to an operating pressure of 1200 bar. The StableBond Aq packing is made by chemically bonding a reversed-phase proprietary alkyl group to a specially prepared, high-purity Agilent ZORBAX porous silica microsphere. The special ZORBAX silica support is designed to reduce or eliminate strong adsorption of basic compounds. The densely covered, sterically protected stationary phase is chemically stable and gives longer column life. As a result, Agilent ZORBAX SB-Aq is a stable, reversed-phase packing that can be used for basic, neutral, or acidic samples. It is particularly well-suited for use with aggressive mobile phases (for example, pH < 2, high ionic strength, ion-pair additives) since the steric protection of the bonded phase resists degradation caused by such mobile phases. This material has also been shown to be stable when operated at temperatures up to 80 °C. These characteristics are particularly important for use in methods that need long-term stability and reproducibility. ZORBAX SB-Aq is especially suited in applications that use high-sensitivity detectors that require low backgrounds (for example, mass spectrometers).


Agilent ZORBAX SB-Aq Rapid Resolution High Definition Threaded Column Data Sheet - cover page
Brand
Agilent
Category
Other
Document type
Datasheet
Language
English
Pages
2
File format
PDF
File size
138 KB
Published
04 July, 2012
Updated
28 September, 2023
MD5 checksum
0C51A7D5582F73CEF0FE387A362D0EFC

About this manual

The Agilent ZORBAX SB-Aq Rapid Resolution High Definition (RRHD) threaded columns are specifically designed for use with ultra-high performance liquid chromatographs (UHPLCs) such as the Agilent 1290 Infinity LC. These columns operate safely up to a maximum pressure of 1200 bar and feature StableBond Ag packing made by chemically bonding a reversed-phase proprietary alkyl group to high-purity Agilent ZORBAX porous silica microspheres. The special silica support is designed to reduce or eliminate strong adsorption of basic compounds, providing longer column life and stability.

What's inside

  • General Description
  • Column Characteristics
  • Safety Considerations
  • Operational Guidelines
  • Mobile Phase Selection
  • Applications
  • Column Care
  • Storage Recommendations

Specifications

Maximum operating pressure1200 bar
Maximum operating temperature80 °C
Particle pore size80A
Compatible instrumentsAgilent 1290 Infinity LC

Frequently asked questions

What is the maximum operating pressure for these columns?

The maximum operating pressure is 1200 bar (17,000 psi).

What is the recommended storage solvent for long-term storage?

Long-term storage should be in a pure organic solvent, preferably an aprotic liquid such as 100% acetonitrile.

Are these columns suitable for basic compounds?

Yes, the ZORBAX SB-Aq is particularly well-suited for use with aggressive mobile phases and is stable for basic, neutral, or acidic samples.