Determination of Butyltin Compounds in Environmental Samples by Isotope Dilution GC-MS Application Note

The method is based on the use of a mixed 119Sn-enriched spike and uses GC-MS coupled with electron impact ionization to simultaneously determine monobutyl, dibutyl, and tributyltin in water, sediments, and biota.


Determination of Butyltin Compounds in Environmental Samples by Isotope Dilution GC-MS Application Note - cover page
Brand
Agilent
Document type
Other
Language
English
Pages
6
File format
PDF
File size
75 KB
Published
02 July, 2012
Updated
30 September, 2023
MD5 checksum
C9BABC3FCA21FAC1FA846CD18F17FEC7

About this manual

The document presents an application note detailing the development of a speciation method for the simultaneous determination of monobutyltin (MBT), dibutyltin (DBT), and tributyltin (TBT) in environmental samples, including waters, sediments, and biota. The method utilizes gas chromatography-mass spectrometry (GC-MS) with electron impact ionization and is based on the use of a mixed spike containing 120Sn-enriched MBT, DBT, and TBT for isotope dilution analysis.

The procedure covers sample preparation steps such as extraction from sediments and mussel tissue using acetic acid/methanol mixtures, followed by ethylation with sodium tetraethylborate. Water samples are also processed via liquid-liquid extraction into hexane. The resulting derivatives are analyzed on an Agilent Technologies gas chromatograph model 6890N equipped with an HP-5MS capillary column and an Agilent mass spectrometric detector model 5973 Network MSD.

What's inside

  • Determination of Butyltin Compounds
  • Isotope Dilution Analysis
  • GC-MS Methodology
  • Environmental Samples
  • Sample Preparation
  • Instrumentation Setup
  • Ethylation Procedure
  • Results and Discussion
  • Mass Spectrometry Detection
  • Data Computation

Specifications

Gas Chromatograph ModelAgilent Technologies gas chromatograph model 6890N
Mass Spectrometer ModelAgilent mass spectrometric detector model 5973 Network MSD
Column TypeHP-5MS capillary column (cross-linked 5% phenyl methyl siloxane, 30 m x 0.25 mm id x 0.25 um coating)
Carrier GasHelium with a constant flow of 1.2 mL/min
Ionization Energy70 eV

Frequently asked questions

Which butyltin compounds can be determined simultaneously?

The method allows for the simultaneous determination of monobutyl-, dibutyl-, and tributyltin in environmental samples.

What type of ionization is used for the GC-MS analysis?

The method uses electron impact ionization.