Littelfuse Axial Lead Cartridge Fuses Data Sheet

The 213 series Slo-Blo® fuse is designed to International (IEC) Standards for use globally. It meets the IEC 60127-2, Sheet 3 specification for Time Lag Fuses. It is available in ratings of 0.200 to 6.3 amperes. RoHS and Lead-Free versions are available, add XP suffix to standard catalog number.


Littelfuse Axial Lead Cartridge Fuses Data Sheet - cover page
Brand
Littelfuse
Category
Other Electronics
Document type
Datasheet
Language
English
Pages
4
File format
PDF
File size
231 KB
Published
12 June, 2012
Updated
30 September, 2023
MD5 checksum
D29B78CF089A24E8526E53E9C31321F5

About this manual

This document provides technical specifications for the Littelfuse 213 Series and 218 Series Axial Lead and Cartridge Fuses. These time lag (Slo-Blo) fuses are designed to International (IEC) Standards, specifically meeting the IEC 60127-2, Sheet 3 specification.

What's inside

  • Electrical Characteristics
  • Interrupting Ratings
  • Ordering Information
  • Environmental Specifications
  • Physical Specifications

Specifications

Standard ComplianceIEC 60127-2, Sheet 3 specification for Time Lag Fuses
Operating Temperature-55°C to 125°C
Interrupting Rating (Max)100A @ 250 VAC, unity power factor
Body MaterialGlass
Cap MaterialNickel Plated Brass

Frequently asked questions

Are RoHS compliant and lead-free versions available?

Yes, a lead-free version is available by adding the XP suffix to the standard catalog number.

What are the available ratings for these fuses?

The 213 Series is rated from 0.200 to 6.3 amperes, while the 218 Series ranges from 0.032 to 15 amperes.