Agilent Analysis of Amitriptyline, Fluoxetine, Quetiapine, and Sertraline Using Dried Blood Spots Application Note

The document describes the method of analyzing amitriptyline, fluoxetine, quetiapine, and sertraline using dried blood spots. Blood is spotted onto a blood spotting card and allowed to dry, then samples are taken from the spot for analysis. A new non-cellulose material can also be used for other biological fluids. The use of dried blood spot analysis for drugs is gaining popularity in clinical trials in the pharmaceutical industry.


Agilent Analysis of Amitriptyline, Fluoxetine, Quetiapine, and Sertraline Using Dried Blood Spots Application Note - cover page
Brand
Agilent
Category
Other
Document type
Application Note
Language
English
Pages
4
File format
PDF
File size
322 KB
Published
11 June, 2012
Updated
28 September, 2023
Model
1290 LC
MD5 checksum
0A36CD4726BD354135148BF10DACD4A6

About this manual

This document details a method for analyzing amitriptyline, fluoxetine, quetiapine, and sertraline using dried blood spots (DBS) and a new non-cellulose Dried Matrix Spotting (DMS) media. The procedure involves spotting 15 microliters of blood onto a card, drying it, punching a 2-4 mm core, and desorbing the analytes with solvent for LC-MS/MS analysis.

Experimental results demonstrate the method's performance using an Agilent 1290 LC system coupled with an Agilent 6460 mass spectrometer. The study achieved linearity with correlation coefficients better than 0.995 and relative recoveries within 10% of the true value across three concentration levels (0.5, 5.0, and 500 ng/mL).

What's inside

  • Introduction
  • Experimental Results and Discussion
  • LC/MS Conditions
  • Analyte Recoveries
  • Conclusions

Specifications

ColumnAgilent Poroshell 120 EC-C18 3.0 mm x 50 mm
Mobile Phase A0.1% Aqueous formic acid
Runtime3:00 minutes
Gas temp350 C
Gas flow10 L/min
Nebulizing20 psi

Frequently asked questions

What system was used for the analysis?

The analysis was performed using an Agilent 1290 LC system and an Agilent 6460 mass spectrometer.

What is the recommended drying time for blood spots?

The blood spot should be allowed to dry for at least 2 hours.

What size core is punched from the dried spot?

A 2-4 mm core is punched from the spot for analysis.

Can DMS cards be used for diagnostic procedures?

No, Bond Elut DMS cards are intended for DMPK/ADME research applications only and should not be used in diagnostic procedures.

Download PDF (322 KB)

More Agilent Manuals


View all Agilent manuals →