Analog Devices AD8628/AD8629/AD8630 Operational Amplifier Handbook

The AD8628/AD8629/AD8630 are wide bandwidth auto-zero amplifiers featuring rail-to-rail input and output swing and low noise.


Analog Devices AD8628/AD8629/AD8630 Operational Amplifier Handbook - cover page
Brand
Analog Devices
Category
Other Electronics
Document type
Datasheet
Language
English
Pages
20
File format
PDF
File size
415 KB
Published
04 June, 2012
Updated
30 September, 2023
MD5 checksum
9092FC6353347830E327C09988C1A043

About this manual

The AD8628, AD8629, and AD8630 are zero‑drift, single‑supply operational amplifiers with rail‑to‑rail input and output swing. They offer ultra‑low offset (1 µV min, 5 µV typ), low bias current (30 pA‑100 pA), and low supply current, making them suitable for automotive sensors, pressure and position sensors, strain‑gage amplifiers, medical instrumentation, thermocouple amplifiers, precision current sensing, and photodiode amplifiers.

The document includes detailed electrical characteristics for both 5 V and 2.7 V supply options, absolute maximum ratings, thermal data, ESD precautions, typical performance graphs, and an ordering guide that lists the available TSOT, SOT‑23, SOIC, MSOP, and TSSOP packages.

What's inside

  • Features
  • Applications
  • General Description
  • Pin Configurations
  • Specifications
  • Electrical Characteristics – 5 V
  • Electrical Characteristics – 2.7 V
  • Absolute Maximum Ratings
  • Thermal Characteristics
  • Typical Performance Characteristics

Specifications

Supply Voltage Range2.7 V to 5 V single‑supply
Operating Temperature Range‑40 °C to +125 °C
Input Bias Current (AD8630)100 pA min, 300 pA typ
Gain‑Bandwidth Product (5 V)25 MHz
Gain‑Bandwidth Product (2.7 V)2 MHz
Slew Rate1.0 V/µs
Overload Recovery Time0.05 ms

Frequently asked questions

What supply voltage range do the AD8628/AD8629/AD8630 support?

They operate from 2.7 V to 5 V on a single supply (or 1.35 V to 2.5 V on dual supply).

How fast does the amplifier recover from overload?

The overload recovery time is 0.05 ms.