This document is the Remote-SAT User's Guide for Siemens Cellular Engines version 03. The document provides instructions for testing, evaluation, integration, and information purposes of products such as MC75, TC63, TC65, AC65, AC75, XT65, and XT75. The document includes information about usage risks and disclaimers, and emphasizes that the product is not intended for use in life support appliances. It also highlights the need for applications incorporating the described product to be designed according to technical specifications.
This guide describes the Remote‑SAT interface, which implements the SIM Application Toolkit (SAT) on Siemens cellular engines. It explains the AT command set, proactive and envelope commands, and provides state diagrams and tables for command handling.
The document lists the supported Siemens products (MC75, TC63, TC65, AC65, AC75, XT65, XT75), defines terminology, and includes appendices with SAT profile details, character set options, and language codes.
| Supported products | MC75, TC63, TC65, AC65, AC75, XT65, XT75 |
|---|---|
| SAT class | Class 3 GSM 11.14 Release 99 |
Remote‑SAT supports the MC75, TC63, TC65, AC65, AC75, XT65 and XT75 cellular modules.
It provides AT commands and responses for implementing the SIM Application Toolkit (SAT) on Siemens GSM engines.
Remote‑SAT implements SAT class 3 as defined in GSM 11.14 Release 99.