This document describes the features and characteristics of UNIDRIVE ES elevator solution, including secure disable function, EMC compatibility, ModbusRTU, and LCD display.
This datasheet covers the Control Techniques UNIDRIVE ES Elevator Solution. It lists input voltage and frequency ratings, current and power ratings for ES2402-ES3403 models, dimensions, and optional communication and I/O modules.
The document also states EMC and safety requirements, encoder interface support, protection ratings, operating temperature and humidity limits, and speed and torque data. This manual is written in Chinese.
| Input voltage | 380-480 V (±10%) |
|---|---|
| Input frequency | 48-65 Hz |
| Speed range | 0.00-10.00 m/s |
| Torque | +150% / -150% |
| Encoder interface | SinCos, SSI, F/D, CW/CCW, 400 kHz |
| Protection rating | IP20, IP54, NEMA 2 |
| Safety function | Secure Disable Function; EN 954-1 Category 3 |
| Communication interfaces | Modbus RTU; optional Profibus DP, DeviceNet, CANopen |
The listed input voltage range is 380-480 V (±10%).
The listed input frequency range is 48-65 Hz.
The listed encoder interfaces include SinCos, SSI, F/D and CW/CCW at 400 kHz.
The listed protection ratings are IP20, IP54 and NEMA 2.