This manual provides instructions for the SMC IZS30 series ionizer, a device used for static elimination in factory automation environments. It covers safety warnings, model identification, specifications, installation procedures, cable connections, and functional descriptions.
The document details operating modes such as sensing DC, pulse DC, and DC modes, along with timing charts. It also includes technical data on static elimination characteristics and dimensional drawings. Users are warned about high-voltage hazards and required to follow proper mounting and wiring practices. This manual is written in Japanese.
| Power cable minimum bending radius | 20 mm |
|---|
Both the power cable and sensor cable have a minimum bending radius of 20 mm at 20°C for fixed wiring.
The minimum bend radius is 20 mm for both the power cable and the sensor cable at 20°C for fixed wiring.
The ionizer must be installed away from walls as shown in the diagram; if walls are within the indicated distances, ions may not reach the target effectively.
Only clean compressed air must be used; flammable or explosive gases are strictly prohibited.