YASKAWA III series SGM/SGDS Error A. 930: Absolute Encoder Battery Fault

YASKAWA III series SGM/SGDS servo unit · taken from the manufacturer’s manual, pages cited

Fault codeA. 930

Absolute Encoder Battery Fault means the absolute encoder battery voltage is too low, or there is a servo unit circuit board fault or poor battery connection. The manual's first action is: “Replace servo unit”

Model
YASKAWA III series SGM/SGDS
Display shows
Absolute Encoder Battery Fault (A. 930)
Type
Fault code
Source
Manual p. 292

What A. 930 means

Absolute Encoder Battery Fault p. 303

Common causes

  • Warning that the absolute encoder battery voltage is too low. p. 303
  • Servo unit circuit board fault (when an absolute encoder is used with an incremental encoder system). p. 303
  • Battery connection poor or not connected p. 303
  • Battery voltage below the specified value (2.7 V) p. 303
  • Servo unit circuit board fault p. 303

What to do

  1. Replace servo unit p. 303
  2. Connect the battery correctly p. 303
  3. Replace the battery and restart the PG power supply p. 303

Before you service the product, read the safety instructions in the manual p. 292.

If A. 930 is still not resolved

  • Unless designated personnel, do not perform settings, disassembly, and repair. Otherwise there is danger of electric shock or injury. p. 6
    “除非是指定的人员,否则不要进行设置、拆卸与修理。否则会有触电或导致受伤的危险。”
  • Contact designated personnel for settings, disassembly, and repair to avoid electric shock or injury. p. 6
    “除非是指定的人员,否则不要进行设置、拆卸与修理。否则会有触电或导致受伤的危险。”

This page summarises what the manufacturer’s manual says about A. 930; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with YASKAWA. Found a mistake? Report an error.