Vibration means abnormal motor speed vibration detected, possibly due to incorrect servo unit gain or an inertia ratio larger than the actual value. The manual's first action is: “To set correct gains, reduce speed loop gain (Pn100) and position loop gain (Pn101), and increase filter time constants such as torque command filter (Pn401).”
- Model
- YASKAWA III series SGM/SGDS
- Display shows
- Vibration (A. 911)
- Type
- Warning code
- Source
- Manual p. 292
What A. 911 means
Vibration p. 303
Common causes
- Abnormal motor speed vibration detected, matching A.520 detection value; vibration detection switch Pn310 determines whether it is an alarm or a warning. p. 303
- Incorrect servo unit gain p. 303
- The inertia ratio (Pn103) is larger than the actual value or has changed significantly p. 303
What to do
- To set correct gains, reduce speed loop gain (Pn100) and position loop gain (Pn101), and increase filter time constants such as torque command filter (Pn401). p. 303
- Properly set the inertia ratio (Pn103). p. 303
Before you service the product, read the safety instructions in the manual p. 292.
If A. 911 is still not resolved
- Unless designated personnel, do not perform settings, disassembly, and repair. Otherwise there is danger of electric shock or injury. p. 6 “除非是指定的人员,否则不要进行设置、拆卸与修理。否则会有触电或导致受伤的危险。”
- Contact designated personnel for settings, disassembly, and repair to avoid electric shock or injury. p. 6 “除非是指定的人员,否则不要进行设置、拆卸与修理。否则会有触电或导致受伤的危险。”
This page summarises what the manufacturer’s manual says about A. 911; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with YASKAWA. Found a mistake? Report an error.