YASKAWA III series SGM/SGDS Error A. 94B: Data Setting Warning 2 (Data Out of Range)

YASKAWA III series SGM/SGDS servo unit · taken from the manufacturer’s manual, pages cited

Warning codeA. 94B

Data Setting Warning 2 (Data Out of Range) means command data is out of range or values set in the command data are outside the allowed range. The manual's first action is: “Set values within the allowed range”

Model
YASKAWA III series SGM/SGDS
Display shows
Data Setting Warning 2 (Data Out of Range) (A. 94B)
Type
Warning code
Source
Manual p. 292

What A. 94B means

Data Setting Warning 2 (Data Out of Range) p. 304

Common causes

  • Command data is out of range p. 304
  • Values set in the command data are outside the allowed range p. 304

What to do

  1. Set values within the allowed range p. 304

Before you service the product, read the safety instructions in the manual p. 292.

If A. 94B is still not resolved

  • Unless designated personnel, do not perform settings, disassembly, and repair. Otherwise there is danger of electric shock or injury. p. 6
    “除非是指定的人员,否则不要进行设置、拆卸与修理。否则会有触电或导致受伤的危险。”
  • Contact designated personnel for settings, disassembly, and repair to avoid electric shock or injury. p. 6
    “除非是指定的人员,否则不要进行设置、拆卸与修理。否则会有触电或导致受伤的危险。”

This page summarises what the manufacturer’s manual says about A. 94B; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with YASKAWA. Found a mistake? Report an error.