YASKAWA III series SGM/SGDS Error A. 920: Regenerative Overload

YASKAWA III series SGM/SGDS servo unit · taken from the manufacturer’s manual, pages cited

Alarm codeA. 920

Regenerative Overload means a warning that a regenerative overload alarm (A.320) is imminent if continued operation occurs, or there is a servo unit circuit board fault or excessive regenerative energy. The manual's first action is: “Replace servo unit”

Model
YASKAWA III series SGM/SGDS
Display shows
Regenerative Overload (A. 920)
Type
Alarm code
Source
Manual p. 292

What A. 920 means

Regenerative Overload p. 303

Common causes

  • Warning that a regenerative overload alarm (A.320) is imminent; continued operation may trigger the alarm. p. 303
  • Servo unit circuit board fault p. 303
  • Excessive regenerative energy p. 303
  • Continuous regenerative operation p. 303
  • User parameter Pn600 capacity setting is smaller than the external regenerative resistor capacity p. 303
  • Servo unit fault p. 303

What to do

  1. Replace servo unit p. 303
  2. Select a different regenerative resistor capacity or re‑evaluate load and operating conditions p. 303
  3. Calibrate the user parameter Pn600 setting p. 303

Before you service the product, read the safety instructions in the manual p. 292.

If A. 920 is still not resolved

  • Unless designated personnel, do not perform settings, disassembly, and repair. Otherwise there is danger of electric shock or injury. p. 6
    “除非是指定的人员,否则不要进行设置、拆卸与修理。否则会有触电或导致受伤的危险。”
  • Contact designated personnel for settings, disassembly, and repair to avoid electric shock or injury. p. 6
    “除非是指定的人员,否则不要进行设置、拆卸与修理。否则会有触电或导致受伤的危险。”

This page summarises what the manufacturer’s manual says about A. 920; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with YASKAWA. Found a mistake? Report an error.