Fault codeA. 901
Excessive Position Deviation When Gap ON means accumulated position deviation pulses exceed the user limit when gap is ON, or there is motor wiring abnormality. The manual's first action is: “(Pn526 × Pn528) / 100”
- Model
- YASKAWA III series SGM/SGDS
- Display shows
- Excessive Position Deviation When Gap ON (A. 901)
- Type
- Fault code
- Source
- Manual p. 292
What A. 901 means
Excessive Position Deviation When Gap ON p. 292
Common causes
- When gap is ON, accumulated position deviation pulses exceed the user limit p. 292
- Position deviation pulses are too large when servo is OFF p. 292
- Motor wiring abnormal (poor wiring or bad connections) p. 292
- Encoder wiring abnormal (poor wiring or bad connections) p. 292
- Servo unit fault p. 292
- Startup torque exceeds maximum torque p. 292
- Effective torque exceeds rated torque p. 292
- High temperature inside the servo unit’s storage compartment p. 292
What to do
- (Pn526 × Pn528) / 100 p. 292
- Set servo OFF so that the servo motor does not move p. 292
- Correct motor wiring p. 292
- Correct encoder wiring p. 292
- Replace servo unit p. 292
- Re‑study load conditions, operating conditions, or motor capacity p. 292
- Reduce internal temperature to below 55 °C p. 292
Before you service the product, read the safety instructions in the manual p. 292.
If A. 901 is still not resolved
- Unless designated personnel, do not perform settings, disassembly, and repair. Otherwise there is danger of electric shock or injury. p. 6 “除非是指定的人员,否则不要进行设置、拆卸与修理。否则会有触电或导致受伤的危险。”
- Contact designated personnel for settings, disassembly, and repair to avoid electric shock or injury. p. 6 “除非是指定的人员,否则不要进行设置、拆卸与修理。否则会有触电或导致受伤的危险。”
This page summarises what the manufacturer’s manual says about A. 901; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with YASKAWA. Found a mistake? Report an error.