DB Overload means a warning that a DB overload alarm (A.731) is imminent if continued operation occurs, or there is a servo unit circuit board fault or rotational energy during DB stop exceeds the DB resistor’s capacity. The manual's first action is: “Replace servo unit”
- Model
- YASKAWA III series SGM/SGDS
- Display shows
- DB Overload (A. 921)
- Type
- Alarm code
- Source
- Manual p. 292
What A. 921 means
DB Overload p. 303
Common causes
- Warning that a DB overload alarm (A.731) is imminent; continued operation may trigger the alarm. p. 303
- Servo unit circuit board fault p. 303
- Rotational energy during DB stop exceeds the DB resistor’s capacity p. 303
- Servo unit fault p. 303
What to do
- Replace servo unit p. 303
- Re‑consider the following: (1) lower the servo motor operating speed, (2) reduce load inertia, (3) reduce DB stop frequency p. 303
Before you service the product, read the safety instructions in the manual p. 292.
If A. 921 is still not resolved
- Unless designated personnel, do not perform settings, disassembly, and repair. Otherwise there is danger of electric shock or injury. p. 6 “除非是指定的人员,否则不要进行设置、拆卸与修理。否则会有触电或导致受伤的危险。”
- Contact designated personnel for settings, disassembly, and repair to avoid electric shock or injury. p. 6 “除非是指定的人员,否则不要进行设置、拆卸与修理。否则会有触电或导致受伤的危险。”
This page summarises what the manufacturer’s manual says about A. 921; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with YASKAWA. Found a mistake? Report an error.