YASKAWA III series SGM/SGDS Error A. F10: Phase Loss in Power Cable

YASKAWA III series SGM/SGDS servo unit · taken from the manufacturer’s manual, pages cited

Fault codeA. F10

This code indicates one phase of the three-phase main power circuit is not connected when the control power is turned on or when the main power is turned on. The manual's first action is: “Zero‑speed stop”

Model
YASKAWA III series SGM/SGDS
Display shows
Phase Loss in Power Cable (A. F10)
Type
Fault code
Source
Manual p. 291

What A. F10 means

Phase Loss in Power Cable p. 291

Common causes

  • One phase of the three‑phase main power circuit is not connected p. 291
  • Occurs when the control power is turned on p. 291
  • Occurs when the main power is turned on p. 291
  • Three‑phase power imbalance p. 291
  • Servo unit fault p. 291
  • Occurs while driving the servo motor p. 291

What to do

  1. Zero‑speed stop p. 291
  2. Servo unit fault – replace servo unit p. 291
  3. Poor three‑phase wiring – correct power wiring p. 291
  4. Correct power imbalance (swap phases) p. 291
  5. Replace servo unit p. 291
  6. Loose three‑phase connections – correct power wiring p. 291
  7. Correct power imbalance p. 291

Before you service the product, read the safety instructions in the manual p. 292.

If A. F10 is still not resolved

  • Unless designated personnel, do not perform settings, disassembly, and repair. Otherwise there is danger of electric shock or injury. p. 6
    “除非是指定的人员,否则不要进行设置、拆卸与修理。否则会有触电或导致受伤的危险。”
  • Contact designated personnel for settings, disassembly, and repair to avoid electric shock or injury. p. 6
    “除非是指定的人员,否则不要进行设置、拆卸与修理。否则会有触电或导致受伤的危险。”

This page summarises what the manufacturer’s manual says about A. F10; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with YASKAWA. Found a mistake? Report an error.