An overrun signal error has occurred due to unmatched enable signals or hardware failure. The manual's first action is: “(1)Reset the alarm. (2)If the alarm occurs again, confirm the followings. - Select "OVERRUN & S-SENSOR"from "ROBOT" menu to display OVERRUN & S-SENSOR window. The alarm can be released on this window.”
- Model
- Yaskawa FS100
- Display shows
- OVERRUN SIGNAL ERROR (OT1) (4836)
- Type
- Alarm code
- Source
- Manual p. 297
What 4836 means
OVERRUN SIGNAL ERROR (OT1) p. 297
Common causes
- Enable signal unmatched error p. 297
- Connection failure p. 297
- Hardware failure p. 297
- Machine safety board failure p. 297
What to do
- (1)Reset the alarm. (2)If the alarm occurs again, confirm the followings. - Select "OVERRUN & S-SENSOR"from "ROBOT" menu to display OVERRUN & S-SENSOR window. The alarm can be released on this window. p. 297
- (1)Reset the alarm. (2)If the alarm occurs again, execute the following operation. - Replacement of the connection cable p. 297
- (1)Reset the alarm. (2)If the alarm occurs again, execute the following operation. - Replacement of the limit switch or corresponding parts. p. 297
- (1)Reset the alarm. (2)If the alarm occurs again, save the CMOS BIN in maintenance mode, and then contact your Yaskawa representative about occurrence status (operating procedure). p. 297
Before you service the product, read the safety instructions in the manual p. 4.
If 4836 is still not resolved
- (1)Reset the alarm. (2)If the alarm occurs again, save the CMOS BIN in maintenance mode, and then contact your Yaskawa representative about occurrence status (operating procedure). p. 297 “(1)Reset the alarm. (2)If the alarm occurs again, save the CMOS BIN in maintenance mode, and then contact your Yaskawa representative about occurrence status (operating procedure).”
This page summarises what the manufacturer’s manual says about 4836; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Yaskawa. Found a mistake? Report an error.