Yaskawa FS100 Error 4672: BASIC SPEED UNREACHED

Yaskawa FS100 · taken from the manufacturer’s manual, pages cited

Alarm code4672

The axis did not reach the specified basic speed. The manual's first action is: “Increase the speed specification value of a measurement job or set a small value for BASICV. Or set a small value for BASIC T, or lengthen the measurement section.”

Model
Yaskawa FS100
Display shows
BASIC SPEED UNREACHED (4672)
Type
Alarm code
Source
Manual p. 280

What 4672 means

BASIC SPEED UNREACHED p. 280

Common causes

  • Sub Code: Signifies the axis in which the alarm occurred p. 280

What to do

  1. Increase the speed specification value of a measurement job or set a small value for BASICV. Or set a small value for BASIC T, or lengthen the measurement section. p. 280

If 4672 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Yaskawa service.

This page summarises what the manufacturer’s manual says about 4672; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Yaskawa. Found a mistake? Report an error.