Yaskawa FS100 Error 4656: WRONG EXECUTION OF SETPRM INST

Yaskawa FS100 · taken from the manufacturer’s manual, pages cited

Alarm code4656

The SETPRM instruction attempted to change a parameter not related to the cube. The manual's first action is: “(1)Check the following settings. - The SETPRM instruction cannot change the parameter values other than the parameter related to the cube. Correct the setting of tag that specifies parameter number of SETPRM instruction.”

Model
Yaskawa FS100
Display shows
WRONG EXECUTION OF SETPRM INST (4656)
Type
Alarm code
Source
Manual p. 280

What 4656 means

WRONG EXECUTION OF SETPRM INST p. 280

Common causes

  • An attempt was made to change a parameter other than the cube-related parameter. p. 280

What to do

  1. (1)Check the following settings. - The SETPRM instruction cannot change the parameter values other than the parameter related to the cube. Correct the setting of tag that specifies parameter number of SETPRM instruction. p. 280

If 4656 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Yaskawa service.

This page summarises what the manufacturer’s manual says about 4656; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Yaskawa. Found a mistake? Report an error.