Sub Code: MOTOWELD's Err Code. indicates an abnormal movement of PLD causing the welding power supply to reboot, requiring replacement of main board with part code Pr (MB)-030 and contacting Yaskawa representative. The manual's first action is: “(1)Movement abnormality of PLD occurred, and a welding power supply rebooted.. (2)Replace the main board [Pr (MB)-030]. Contact your Yaskawa representative.”
- Model
- Yaskawa 2DX200
- Display shows
- Sub Code: MOTOWELD's Err Code. (400)
- Type
- Alarm code
- Source
- Manual p. 65
What 400 means
Sub Code: MOTOWELD's Err Code. p. 65
What to do
- (1)Movement abnormality of PLD occurred, and a welding power supply rebooted.. (2)Replace the main board [Pr (MB)-030]. Contact your Yaskawa representative. p. 65
Before you service the product, read the safety instructions in the manual p. 2.
If 400 is still not resolved
- If your copy of the manual is damaged or lost, contact a YASKAWA representative to order a new copy. p. 2 “If your copy of the manual is damaged or lost, contact a YASKAWA representative to order a new copy.”
This page summarises what the manufacturer’s manual says about 400; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Yaskawa. Found a mistake? Report an error.