Yaskawa 2DX200 Error 320: Sub Code: MOTOWELD's Err Code.

Industrial robot · taken from the manufacturer’s manual, pages cited

Alarm code320

Sub Code: MOTOWELD's Err Code. means a connection or dip switch issue between front panel and main board, requiring checking status, replacing components as needed. The manual's first action is: “(1)Check the connection between front panel and main board. (2)Check the status of dip switch (SV301) on the front panel. (3)Replace the front panel. (4)Replace the main board.”

Model
Yaskawa 2DX200
Display shows
Sub Code: MOTOWELD's Err Code. (320)
Type
Alarm code
Source
Manual p. 65

What 320 means

Sub Code: MOTOWELD's Err Code. p. 65

What to do

  1. (1)Check the connection between front panel and main board. (2)Check the status of dip switch (SV301) on the front panel. (3)Replace the front panel. (4)Replace the main board. p. 65

Before you service the product, read the safety instructions in the manual p. 2.

If 320 is still not resolved

  • If your copy of the manual is damaged or lost, contact a YASKAWA representative to order a new copy. p. 2
    “If your copy of the manual is damaged or lost, contact a YASKAWA representative to order a new copy.”

This page summarises what the manufacturer’s manual says about 320; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Yaskawa. Found a mistake? Report an error.