Alarm code12
Motor's speed is 1.5 times more than motor's rated speed. The manual's first action is: “1. Reduce the speed command. 2. Electronic gear ratio is incorrect check and set correctly. 3. Adjust speed loop gains (Sn211 & Sn213) for a better motor response.”
- Model
- TED TSTE Series
- Display shows
- Motor over speed (12)
- Type
- Alarm code
- Source
- Manual p. 189
What 12 means
Motor over speed p. 189
Common causes
- Motor's speed is 1.5 times more then motor's rated speed. p. 189
What to do
- 1. Reduce the speed command. 2. Electronic gear ratio is incorrect check and set correctly. 3. Adjust speed loop gains (Sn211 & Sn213) for a better motor response. p. 189
- Turn ALRS (DI) ON p. 189
If 12 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact TED service.