TED TSTE Series Error 05: RTU CHECK FAILURE

TED TSTE Series · taken from the manufacturer’s manual, pages cited

Error code05

RTU CHECK FAILURE indicates a CRC check error or encoder failure/connection problem The manual's first action is: “1. Check the motor's encoder connections. 2. Check the encoder if short circuit, poor solder joints or break. 3. Check the encoder signal terminals CN2-4 and CN2-5 ( power cable 5V)”

Model
TED TSTE Series
Display shows
RTU CHECK FAILURE (05)
Type
Error code
Source
Manual p. 179

What 05 means

RTU CHECK FAILURE p. 188

Common causes

  • RTU mode: CRC check error p. 188
  • Motor's encoder failure or encoder connection problem. p. 188

What to do

  1. 1. Check the motor's encoder connections. 2. Check the encoder if short circuit, poor solder joints or break. 3. Check the encoder signal terminals CN2-4 and CN2-5 ( power cable 5V) p. 188

If 05 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact TED service.

This page summarises what the manufacturer’s manual says about 05; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with TED. Found a mistake? Report an error.