RTU CHECK FAILURE indicates a CRC check error or encoder failure/connection problem The manual's first action is: “1. Check the motor's encoder connections. 2. Check the encoder if short circuit, poor solder joints or break. 3. Check the encoder signal terminals CN2-4 and CN2-5 ( power cable 5V)”
- Model
- TED TSTE Series
- Display shows
- RTU CHECK FAILURE (05)
- Type
- Error code
- Source
- Manual p. 179
What 05 means
RTU CHECK FAILURE p. 188
Common causes
What to do
- 1. Check the motor's encoder connections. 2. Check the encoder if short circuit, poor solder joints or break. 3. Check the encoder signal terminals CN2-4 and CN2-5 ( power cable 5V) p. 188
If 05 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact TED service.