TED TSTE Series Error 10: Motor over-current

TED TSTE Series · taken from the manufacturer’s manual, pages cited

Alarm code10

Motor over-current occurs when current exceeds four times rated current. The manual's first action is: “1. Check if the motor wiring U,V,W)and encoder wiring correct or not. 2. Internal interference and mal-function . Ensure that all connection are correct ,refer to Chapter 2 Power and motor circuit diagrams.”

Model
TED TSTE Series
Display shows
Motor over-current (10)
Type
Alarm code
Source
Manual p. 189

What 10 means

Motor over-current p. 189

Common causes

  • Motor current is 4 times greater than rated current. p. 189

What to do

  1. 1. Check if the motor wiring U,V,W)and encoder wiring correct or not. 2. Internal interference and mal-function . Ensure that all connection are correct ,refer to Chapter 2 Power and motor circuit diagrams. p. 189
  2. Turn ALRS(DI) ON p. 189

If 10 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact TED service.