TED TSTE Series Error 11: Position error

TED TSTE Series · taken from the manufacturer’s manual, pages cited

Alarm code11

The deviation between Pulse command and encoder feedback is greater than the setting of Pn308 or Pn309. The manual's first action is: “1. Increase the position loop gain (Pn310 and Pn311) setting value. 2. Increase in position tolerance value by (Pn312 for a better motor response. 3. Extend the time of ac/deceleration or reduce load inertia in the permitted range. 4. Check if the motor wiring (U,V,W) is correct.”

Model
TED TSTE Series
Display shows
Position error (11)
Type
Alarm code
Source
Manual p. 189

What 11 means

Position error p. 189

Common causes

  • The deviation between Pulse command and encoder feed back ( position error) is greater than the setting of Pn308 or Pn309. p. 189

What to do

  1. 1. Increase the position loop gain (Pn310 and Pn311) setting value. 2. Increase in position tolerance value by (Pn312 for a better motor response. 3. Extend the time of ac/deceleration or reduce load inertia in the permitted range. 4. Check if the motor wiring (U,V,W) is correct. p. 189
  2. Turn ALRS (DI) ON p. 189

If 11 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact TED service.

This page summarises what the manufacturer’s manual says about 11; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with TED. Found a mistake? Report an error.