TED TSTE Series Error 03: ILLEGAL DATA VALUE

TED TSTE Series · taken from the manufacturer’s manual, pages cited

Error code03

The drive has detected an illegal data value or exceeded its rated load during continuous operation. The manual's first action is: “1. Check connection for Motor terminal s (U,V,W) and Encoder. 2. Adjust the Drive gain, If gain is not correctly adjusted, it would cause motor vibration and large current will lead to motor over load. 3. Extend acc/deceleration time or reduce load ratio in the permitted range.”

Model
TED TSTE Series
Display shows
ILLEGAL DATA VALUE (03)
Type
Error code
Source
Manual p. 179

What 03 means

ILLEGAL DATA VALUE p. 188

Common causes

  • A value contained in the query data field is not an allowable value for server (or slave). p. 188
  • The drive has exceeded its rated load during continuous operation. When the loading is equal to 2 times of rated loading, alarm occurs within 10sec. p. 188

What to do

  1. 1. Check connection for Motor terminal s (U,V,W) and Encoder. 2. Adjust the Drive gain, If gain is not correctly adjusted, it would cause motor vibration and large current will lead to motor over load. 3. Extend acc/deceleration time or reduce load ratio in the permitted range. p. 188

If 03 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact TED service.

This page summarises what the manufacturer’s manual says about 03; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with TED. Found a mistake? Report an error.