TED TSTE Series Error 06: ASCII CHECK FAILURE

TED TSTE Series · taken from the manufacturer’s manual, pages cited

Error code06

ASCII CHECK FAILURE indicates a communication error or timeout in data transmission. The manual's first action is: “1. Check parameter setting of communication function. 2. Check wire connection between drive and controller. 3. Set a correct value for parameter Cn039 communication time-out or set "0" to disable communication time-out function.”

Model
TED TSTE Series
Display shows
ASCII CHECK FAILURE (06)
Type
Error code
Source
Manual p. 179

What 06 means

ASCII CHECK FAILURE p. 188

Common causes

  • ASCIl mode: LRC check error or no end code(CRLF) p. 188
  • Communication protocol setting error or Communication time-out is detected. p. 188

What to do

  1. 1. Check parameter setting of communication function. 2. Check wire connection between drive and controller. 3. Set a correct value for parameter Cn039 communication time-out or set "0" to disable communication time-out function. p. 188

If 06 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact TED service.