Over‑Torque Detection means inverter output torque exceeds parameter 08‑15 for longer than the time set in 08‑16, or mechanical load is excessive. The manual's first action is: “Check the application or operating condition”
- Model
- TECO A510
- Display shows
- Over‑Torque Detection (OT)
- Type
- Error code
- Source
- Manual p. 249
What OT means
Over‑Torque Detection p. 249
Common causes
- Inverter output torque exceeds parameter 08‑15 (over‑torque detection level) for longer than the time set in 08‑16, causing the inverter to activate base‑cutoff (08‑14 = 0) p. 249
- Mechanical load is excessive p. 249
What to do
- Check the application or operating condition p. 249
- Verify that parameters 08‑15 and 08‑16 are set appropriately p. 249
Before you service the product, read the safety instructions in the manual p. 252.
If OT is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact TECO service.
This page summarises what the manufacturer’s manual says about OT; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with TECO. Found a mistake? Report an error.