Output Phase Loss means output cable or motor internal damage, loose or missing terminal screws on R/L1, S/L2, or T/L3, or motor rating is less than 10% of the inverter's rated capacity. The manual's first action is: “Inspect motor wiring”
- Model
- TECO A510
- Display shows
- Output Phase Loss (OPL)
- Type
- Error code
- Source
- Manual p. 249
What OPL means
Output Phase Loss p. 249
Common causes
- Output cable or motor internal damage p. 249
- Loose or missing terminal screws on R/L1, S/L2, or T/L3 p. 249
- Motor rating is less than 10% of the inverter's rated capacity p. 249
What to do
Before you service the product, read the safety instructions in the manual p. 252.
If OPL is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact TECO service.