Heat Sink Overtemperature means heat sink temperature is too high, ambient temperature is too high, or cooling fan has stopped. The manual's first action is: “Check the inverter's surrounding ambient temperature”
- Model
- TECO A510
- Display shows
- Heat Sink Overtemperature (OH1)
- Type
- Error code
- Source
- Manual p. 249
What OH1 means
Heat Sink Overtemperature p. 249
Common causes
- Heat sink temperature is too high p. 249
- Ambient temperature is too high p. 249
- Cooling fan has stopped p. 249
- Carrier frequency setting is too high p. 249
What to do
- Check the inverter's surrounding ambient temperature p. 249
- Inspect fan and heat sink for dust and debris p. 249
- Verify carrier frequency setting p. 249
Before you service the product, read the safety instructions in the manual p. 252.
If OH1 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact TECO service.