TECO A510 Error OS: Over‑Speed

TECO A510 inverter · taken from the manufacturer’s manual, pages cited

Fault codeOS

Over‑Speed means motor speed exceeds parameter 20‑20 for longer than the time set in 20‑21, or if parameter 20‑19 = 0 or 1, the inverter shuts down. The manual's first action is: “Check speed reference gain and the settings of 20‑20 and 20‑21 for appropriateness. Adjust the ASR Group 21 parameter as needed.”

Model
TECO A510
Display shows
Over‑Speed (OS)
Type
Fault code
Source
Manual p. 250

What OS means

Over‑Speed p. 250

Common causes

  • Motor speed exceeds parameter 20‑20 (PG over‑speed setting) for longer than the time set in 20‑21 (PG over‑speed time). p. 250
  • If parameter 20‑19 = 0 or 1, the inverter shuts down. p. 250
  • This fault detection is only active in V/F+PG and SV control modes (00‑00 = 1, 3, or 4). p. 250

What to do

  1. Check speed reference gain and the settings of 20‑20 and 20‑21 for appropriateness. Adjust the ASR Group 21 parameter as needed. p. 250
  2. Speed reference is too high, causing excessive or insufficient response. p. 250
  3. Check speed reference gain and verify the values of 20‑20 and 20‑21. p. 250
  4. Adjust ASR settings (Group 20 parameters). p. 250

Before you service the product, read the safety instructions in the manual p. 252.

If OS is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact TECO service.