Taian S310 Series Error Codes

25 codes from pages 50–51 of the manual

This is the list of fault, error codes the Taian manual gives for the S310 Series Taian S310 Series AC Motor Drive. Find your code below and open it for what the manual says about its causes and what to do.

Fault codes from p. 50

CodeDisplay messageWhat it meansPage
-OV- Overvoltage while stopped 停机中电压过高 p. 50
-LV- Undervoltage while stopped 停机中电压过低 p. 50
-OH- Inverter overtemperature while stopped 停机中变频器过热 p. 50
CTER Current sensor detection error 电流传感器侦测错误 p. 50
EPR EEPROM fault EEPROM 异常 p. 50
COT Communication fault 通讯异常 p. 50
OC Overcurrent while stopped 停机中过电流 p. 50
Err7 Parameter setting error 参数设定错误 p. 51

Error codes from p. 50

CodeDisplay messageWhat it meansPage
OC-S Overcurrent at start‑up 启动瞬间过电流 p. 50
OC-D Overcurrent during deceleration 减速时过电流 p. 50
OC-A Overcurrent during acceleration 加速时过电流 p. 50
OC-C Overcurrent during constant speed 定速中过电流 p. 50
OV-C Overvoltage during operation/deceleration 运转中/减速中电压过高 p. 50
OH-C Heat sink overtemperature during operation 运转中散热片过热 p. 50
OL1 Motor overload 电机过载 p. 50
OL2 Inverter overload 变频器过载 p. 50
LV-C Undervoltage during operation 运转中电压过低 p. 50
STP0 Stopped at zero speed 零速停止中 p. 51
STP1 Direct start failure 直接启动失效 p. 51
STP2 Keyboard emergency stop 键盘紧急停止 p. 51
E.S. External emergency stop 外部紧急停止 p. 51
b.b. External rapid stop (BASE BLOCK) 外部速断 BASE BLOCK p. 51
Err2 Parameter setting error 参数设定错误 p. 51
Err5 Parameter change ineffective during communication 通讯中,修改参数无效 p. 51
Err6 Communication failure 通讯失败 p. 51

Codes and descriptions are taken from the manufacturer’s manual; page numbers link to the PDF. ManualLib is not affiliated with Taian. Found a mistake? Report an error.