Error codeb.b.

The inverter stops output when an external rapid-stop signal is received via the multifunction input terminals. The manual lists no action for this code.

Model
Taian S310 Series
Display shows
External rapid stop (BASE BLOCK) (b.b.)
Type
Error code
Source
Manual p. 51

What b.b. means

External rapid stop (BASE BLOCK) p. 51

Common causes

  • When an external rapid‑stop signal is received via the multifunction input terminals, the inverter immediately ceases output and the b.b. code flashes (see sections 01-00 to 01-04 for details). p. 51

If b.b. is still not resolved

  • Contact Taian Technology regional dealers or technical personnel for difficult problems. p. 5
    “当您在使用过程中发现疑难问题时,请与台安科技各地区经销商或本公司技术人员联系”
  • Contact Taian Technology technical personnel immediately if damage is found. p. 5
    “若有损坏请勿接入电源。z 当您发现有上述问题时请立即通知台安科技各区技术人员”

This page summarises what the manufacturer’s manual says about b.b.; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Taian. Found a mistake? Report an error.