Taian S310 Series Error OV-C: Overvoltage during operation/deceleration

Taian S310 Series AC Motor Drive · taken from the manufacturer’s manual, pages cited

Error codeOV-C

Overvoltage during operation or deceleration means the deceleration time is set too short or the load inertia is large, or there is excessive power supply voltage fluctuation. The manual's first action is: “1. Set a longer deceleration time”

Model
Taian S310 Series
Display shows
Overvoltage during operation/deceleration (OV-C)
Type
Error code
Source
Manual p. 50

What OV-C means

Overvoltage during operation/deceleration p. 50

Common causes

  • 1. Deceleration time set too short or load inertia large p. 50
  • 2. Excessive power supply voltage fluctuation p. 50

What to do

  1. 1. Set a longer deceleration time p. 50
  2. 2. Add a braking resistor or braking module p. 50
  3. 3. Install a reactor on the power input side p. 50
  4. 4. Increase inverter rating p. 50

Before you service the product, read the safety instructions in the manual p. 7.

If OV-C is still not resolved

  • Contact Taian Technology regional dealers or technical personnel for difficult problems. p. 5
    “当您在使用过程中发现疑难问题时,请与台安科技各地区经销商或本公司技术人员联系”
  • Contact Taian Technology technical personnel immediately if damage is found. p. 5
    “若有损坏请勿接入电源。z 当您发现有上述问题时请立即通知台安科技各区技术人员”

This page summarises what the manufacturer’s manual says about OV-C; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Taian. Found a mistake? Report an error.