Error codeOC-A
Overcurrent during acceleration means the acceleration time is set too short, the motor rating exceeds the inverter rating, or the motor winding is shorted to the frame. The manual's first action is: “1. Set a longer acceleration time”
- Model
- Taian S310 Series
- Display shows
- Overcurrent during acceleration (OC-A)
- Type
- Error code
- Source
- Manual p. 50
What OC-A means
Overcurrent during acceleration p. 50
Common causes
- 1. Acceleration time set too short p. 50
- 2. Motor rating exceeds inverter rating p. 50
- 3. Motor winding shorted to the frame p. 50
- 4. Motor wiring shorted to ground p. 50
- 5. IGBT module damaged p. 50
What to do
- 1. Set a longer acceleration time p. 50
- 2. Replace with an inverter of comparable rating p. 50
- 3. Service the motor p. 50
- 4. Inspect wiring p. 50
- 5. Replace IGBT module p. 50
Before you service the product, read the safety instructions in the manual p. 7.
If OC-A is still not resolved
This page summarises what the manufacturer’s manual says about OC-A; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Taian. Found a mistake? Report an error.