Error codeSTP1
Direct start failure means the inverter will not start if power is applied while the run switch is ON when set for external operation and direct-start function is disabled. The manual's first action is: “When 04-09=0, direct start is possible.”
- Model
- Taian S310 Series
- Display shows
- Direct start failure (STP1)
- Type
- Error code
- Source
- Manual p. 51
What STP1 means
Direct start failure p. 51
Common causes
- When the inverter is set for external operation (00-03=1) and the direct‑start function is disabled (04-09=1), if power is applied while the run switch is ON, the inverter will not start and the STP1 code will flash (see the description of 04-09). p. 51
What to do
- When 04-09=0, direct start is possible. p. 51
Before you service the product, read the safety instructions in the manual p. 7.
If STP1 is still not resolved
This page summarises what the manufacturer’s manual says about STP1; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Taian. Found a mistake? Report an error.