Siemens SINAMICS V90, SIMOTICS S-1FL6 Error F7491: STOP cam minus reached

Industrial motor drive · taken from the manufacturer’s manual, pages cited

Fault codeF7491

The STOP cam minus was reached, indicating incorrect wiring for positive direction. The manual's first action is: “Leave the STOP cam minus in the positive traversing direction and return the axis to the valid traversing range.”

Model
Siemens SINAMICS V90, SIMOTICS S-1FL6
Display shows
STOP cam minus reached (F7491)
Type
Fault code
Source
Manual p. 296

What F7491 means

STOP cam minus reached p. 296

Common causes

  • The STOP cam minus was reached. For a positive traversing direction, the STOP cam minus was reached; i.e. the wiring of the STOP cam is incorrect. p. 296

What to do

  1. Leave the STOP cam minus in the positive traversing direction and return the axis to the valid traversing range. p. 296
  2. Check the wiring of the STOP cam. p. 296

Before you service the product, read the safety instructions in the manual p. 2.

If F7491 is still not resolved

  • Contact service / dealer for assistance p. 2
    “Qualified Personnel The product/system described in this documentation may be operated only by personnel qualified for the specific task in accordance with the relevant documentation, in particular its warning notices and safety instructions.”
  • Contact service / dealer for assistance p. 13
    “NOTICE Property damage due to loose power connections Insufficient tightening torques or vibration can result in loose power connections. This can result in damage due to fire, device defects or malfunctions.”

This page summarises what the manufacturer’s manual says about F7491; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Siemens. Found a mistake? Report an error.