Siemens SINAMICS V90, SIMOTICS S-1FL6 Error F7490: Enable signal withdrawn while drawing

Industrial motor drive · taken from the manufacturer’s manual, pages cited

Fault codeF7490

The enable signal was withdrawn while the drive was drawing power, causing it to enter 'switching on inhibited' state. The manual's first action is: “Set the enable signals or check the cause of the fault that first occurred and then reset (for a standard assignment).”

Model
Siemens SINAMICS V90, SIMOTICS S-1FL6
Display shows
Enable signal withdrawn while drawing (F7490)
Type
Fault code
Source
Manual p. 296

What F7490 means

Enable signal withdrawn while drawing p. 296

Common causes

  • For a standard assignment, another fault may have occurred as a result of withdrawing the enable signals. p. 296
  • The drive is in the "switching on inhibited" state (for a standard assignment). p. 296

Safety warnings — read before you start

  • DANGERGeneral Safety Instructions. Qualified Personnel The product/system described in this documentation may be operated only by personnel qualified for the specific task in accordance with the relevant documentation, in particular its warning notices and safety instructions. p. 2
  • WARNINGRisk of Electric Shock and Fire. Risk of electric shock and fire from supply networks with an excessively low impedance Excessively high short-circuit currents can lead to the protective devices not being able to interrupt these short-circuit currents and being destroyed, and thus causing electric shock or a fire. p. 12
  • WARNINGElectric Shock if No Ground Connection. Electric shock if there is no ground connection For missing or incorrectly implemented protective conductor connection for devices with protection class I, high voltages can be present at open, exposed parts, which when touched, can result in death or severe injury. p. 12
  • WARNINGElectric Shock Due to Unsuitable Power Supply. Electric shock due to connection to an unsuitable power supply When equipment is connected to an unsuitable power supply, exposed components may carry a hazardous voltage that might result in serious injury or death. p. 12

What to do

  1. Set the enable signals or check the cause of the fault that first occurred and then reset (for a standard assignment). p. 296
  2. Check the assignment to enable the basic positioning function. p. 296

If F7490 is still not resolved

  • Contact service / dealer for assistance p. 2
    “Qualified Personnel The product/system described in this documentation may be operated only by personnel qualified for the specific task in accordance with the relevant documentation, in particular its warning notices and safety instructions.”
  • Contact service / dealer for assistance p. 13
    “NOTICE Property damage due to loose power connections Insufficient tightening torques or vibration can result in loose power connections. This can result in damage due to fire, device defects or malfunctions.”

This page summarises what the manufacturer’s manual says about F7490; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Siemens. Found a mistake? Report an error.