Fault codeF01663
The SI parameters could not be copied on the Siemens G120C because p9700 was set to 208 or entered offline. The manual's first action is: “- set p9700 to 0.”
- Model
- Siemens G120C
- Display shows
- SI P1 (CU): Copying the SI parameters rejected (F01663)
- Type
- Fault code
- Source
- Manual p. 686
What F01663 means
SI P1 (CU): Copying the SI parameters rejected p. 686
Common causes
- In p9700, the value 208 is saved or was entered offline. p. 686
What to do
- - set p9700 to 0. p. 686
- - Check p9601 and if required, correct. p. 686
- - restart the copying function by entering the corresponding value into p9700. p. 686
Before you service the product, read the safety instructions in the manual p. 4.
If F01663 is still not resolved
This page summarises what the manufacturer’s manual says about F01663; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Siemens. Found a mistake? Report an error.